濡木研公開ラボセミナー

Cryo-EM with the Volta Phase Plate

Radostin Danev博士(Max Planck Institute of Biochemistry)

2017年12月04日(月)    17:30-18:30  理学部2号館 講堂   

Cryo-electron microscopy (cryo-EM) is experiencing a “renaissance” brought about by the development and commercialization of direct electron detectors. In the last few years the typical performance shifted from sub-nanometer (6~10 Å) to near-atomic (< 4 Å) resolutions. This dramatic improvement put cryo-EM in the spotlight and piqued the interest of structural biologists from other fields, such as x-ray crystallography. The higher signal-to-noise ratio provided by direct detectors improved not only the resolution but also the ability to solve the structures of smaller (< 300 kDa) particles [1,2]. However, such particles, although more accessible now, still remain challenging and require the acquisition of big datasets of thousand or more micrographs. Phase plates are one of the technologies holding promise for future improvements in single particle cryo-EM performance, especially for challenging specimens in terms of size, flexibility and heterogeneity.
The Volta phase plate (VPP) is a remarkably simple device comprising a thin (~10 nm) amorphous carbon film positioned at the back focal plane of the objective lens [3]. The film is continuously heated to about 250oC to prevent beam-induced contamination and enable the Volta potential mode of operation. The strong central diffraction beam of unscattered electrons interacts with the film and modifies its surface properties. This creates a Volta potential difference (the contact or outer potential just above the film surface) between the spot of the central diffraction beam and the surrounding areas. This in turn leads to a three-dimensional electrostatic potential distribution above and below the film which when integrated along the beam path leads to a phase shift difference between the central diffraction beam and scattered beams. The effect of the central diffraction beam on the film is cumulative leading to a phase shift which increases with the electron dose. The increase, however, is not linear and slows down as the phase shift approaches ~/2 [3], which coincidently is the ideal phase shift for a phase plate. In practice the non-constant phase shift of the VPP is not a problem because improved image contrast is produced by a wide range of phase shifts, from ~/4 to ~3/4. Thus, many images (~50) can be acquired on a single spot of the VPP film before the phase shift becomes too large (> 3/4) and the phase plate has to be moved to a new spot.
In our lab the VPP is used routinely in cryo-tomography applications where it has already demonstrated remarkable improvements in contrast and visibility of features [4,5]. Single particle applications of the VPP are still in their early days, but the results are very encouraging. The improved contrast (Fig. 1) was instrumental in the near-atomic cryo-EM structure determination of peroxiredoxin-3 (~250 kDa) [6], the nucleosome (~200 kDa) [7], calcitonin class-B GPCR (~150 kDa) [8] and hemoglobin (64 kDa) [9]. The VPP has the potential to extend the applicability of cryo-EM towards smaller particles and it is not unreasonable to expect that in the near future even structures under 50 kDa could be solved to near-atomic resolutions.